Quality control equipment

Serial number inspection device name/model/function/testing specifications note number in good level

1 SY - 01 manual pressure testing machine; For the valve pressure test 1 intact

2 YFSZ - 300 hydraulic pressure testing machine; For the valve pressure test 1 intact

3 vernier caliper class 0 ~ 1000; Used to measure parts axial size 22 in good condition

The depth of 4 '0 ~ 500; Used to measure depth of 10 intact

5 dial indicator used to measure precise size 8 in good condition

6 inner diameter micrometer "class 0 ~ 1200; Used for measuring inner diameter size 5 in good condition

7 outside micrometer "class 0 ~ 1000; Used to measure diameter size 15 in good condition

Height of 8 feet class 250 x 315 x 160/500; Measuring height size 6 in good condition

Universal square of 9 class 0 ~ 300/0 ~ 500; Measuring Angle size 1 intact

10 inner dial indicator 35 ~ 50/160 ~ 250; Used for measuring inner diameter size 13 of the precision in good condition

11 for covering thickness gauge TT210; Measure the paint thickness 1 intact

Class 12 gauge for measuring the pressure of 46 intact

13 TH120 hardness instrument on the Richter scale; Measuring hardness 1 good imports

Digital display JBS - 300 - b semi-automatic impact testing machine; Used in normal temperature or low temperature impact test intact

15 impact test of low temperature tank DWC - 60; Used for low temperature impact test piece of cooling, 1 sound insulation

16 impact specimen gap projector CST - 50; Used in the detection of impact test piece, determine 1 intact

17 NJQ - 3 d carbon sulfur analyzer for element analysis 1 intact

18 non-ferrous metals analyzer NJS - 5 for element analysis 1 intact

19 handheld spectrometer ? 2000; Used to measure chemical composition 1 good imports

20 uv fluorescent D - 10 c for ester inspection 1 intact imports

21 DPL450-175-1.37 type II low temperature test device, used to - 196 ℃ cryogenic treatment 1 intact

22 the helium mass spectrometer leak detector ZQJ - 530 used for low leak detection 1 intact

And low temperature test device DPL450-175-1.37 type II, to - 196 ℃ cryogenic treatment 1 intact

24 computer screen WEW - 300 hydraulic universal testing machine used for tensile test sample 1 b in good condition

25 TLS - S200 spring tension and compression testing machine is used to display the kinetic energy of the spring test 1 in good condition